Fungal Fluorescence Quantitative Rapid Detection Reading Instrument Accuracy :Deviation of target value ≤10%

I'm Online Chat Now

Fungal Fluorescence Quantitative Rapid Detection Reading Instrument Accuracy :Deviation of target value ≤10%

Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10%
Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10% Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10% Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10% Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10% Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10% Fungal Fluorescence Quantitative Rapid Detection Reading Instrument    Accuracy  :Deviation of target value ≤10%

Large Image :  Fungal Fluorescence Quantitative Rapid Detection Reading Instrument Accuracy :Deviation of target value ≤10%

Product Details:
Place of Origin: China
Brand Name: Chenhui
Model Number: CH82064
Payment & Shipping Terms:
Minimum Order Quantity: 1 instrument
Price: Negotiable
Packaging Details: Color Packing
Delivery Time: 5-7 Work Day
Payment Terms: T/T
Supply Ability: 888 PCS

Fungal Fluorescence Quantitative Rapid Detection Reading Instrument Accuracy :Deviation of target value ≤10%

Description
Accuracy: Deviation Of Target Value ≤10% Repeatability: CV≤10%
Stability: CV≤10% Linearity: |r|≥0.99
Storage: -10℃~40℃ Specification: 1
Highlight:

Quantitative Rapid Detection Reading Instrument

,

Fungal Fluorescence Quantitative Rapid Detection

                                    Fungal Fluorescence Quantitative Rapid Detection Reading Instrument

                                                                                             CH82064

 

            

 

3.1 Basic parameters of the instrument

 

illuminant LED
Port RS232,USB
Print Built-in thermal printer
Repeatability CV≤10%
Stability CV≤10%
Accuracy Deviation of target value ≤10%
Linearity Correlation coefficient |r|≥0.99

 

3.2 Transportation and storage conditions of the instrument

After packaging, it should be stored in -10℃ ~ 40℃, relative humidity 20% ~ 90%, atmospheric pressure (70 ~ 106) kPa, no condensation, no corrosive gas and well-ventilated environment. During transportation, attention should be paid to moisture, shock and violent vibration.

 

3.3 Conditions of use of the instrument

 

3.3.1 Positioning and Installation Requirements
1. The instrument should be placed in a stable, level, no serious dust, no direct sunlight, no corrosive gas in the room, the workbench can carry more than 1.5kg weight.
2. There is no strong vibration source or strong electromagnetic field around.
3. It should be placed in a well-ventilated place, and more than 10cm space should be left around the instrument to ensure the necessary space for operation and maintenance.
 

3.3.2 Power Supply Voltage Requirements
The instrument uses 220V/50Hz AC power supply, the input voltage is DC 12V, the instrument power is: 36VA. During use, attention should be paid to avoid the risk of short circuit and electric shock! Note: Files must be consulted in all cases marked with this symbol.
 

3.3.3 The instrument works normally
1. Ambient temperature range: 5℃-40℃.

 

 

 