Description
Rapid: 10min High Recovery: 80 - 105%
Shelf Life: 1 Years Detection Time: 10min
Storage Temperature: 2-8°C Specification: 96T
Highlight:

Milk Samples Food Test Strip

,

10min Food Test Strip

,

96T Food Test Strip

 

                                                            BT Combo Strip Test Kit

                                                                                           CH60023

       

BT Combo Strip Test Kit In Milk Samples

 

 

 

Product Description

 

     BT Combo Strip Test is a qualitative and rapid lateral flow assay designed to detect both beta-lactam and tetracycline antibiotic residues in raw commingled cow’s milk. This test uses a tetracycline receptor and a novel beta-lactam binding protein which eliminates the need for a heating block. This test is designed for point-of-care use or reference lab settings.

 

 

The unique features of the kit are:

 

 

l Rapid strip test method – 7 minutes

l Novel binding protein that requires no heating step

l High sensitivity

l High reproducibility

 

 

Mechanism of Reaction

 

 

       C-line indicates the presence of the corresponding antibiotic in the milk. The greater the reduction in signal intensity at the test line, the greater the concentration of tetracycline or beta-lactam antibiotics present in the milk. The assay is also designed to simultaneously detect tetracycline and beta-lactam antibiotics.

 

 

Kit Contents, Storage and Shelf Life

 

      The  BT Combo Strip Test has the capacity for 96(RNS92005-01) determination. The shelf life is 12 months when the kit is properly stored. The positive and negative control vials contain lyophilized raw milk samples, and must be reconstituted with 1 mL of distilled water before use. The positive control vial is spiked with 4 ppb Penicillin G and 100 ppb of Oxytetracycline. The reconstituted raw milk controls are stable for 48 hours at 4℃. Additional positive and negative control vials are available separately

 

Kit Contents Amount Storage
Reaction wells 4x 24 (96 total)

 

 

4°C

 

Test strips 4 x 24 strips(96 total)
Positive control 1 vial
Negative control 1 vial
Pipette tips 100 tips RT

 

 

 

 

The assay uses a competitive colloidal gold based format. The milk sample (200 μL) is added to a clear plastic reaction vessel, and used to resuspend the lyophilized reagents to a uniform pink color in the bottom of the microtiter wells. The milk is incubated briefly (3 min) to allow the both antibiotic binding proteins on the gold particles to engage with any antibiotic present in the milk.

The test strip is then inserted into the sample well with the arrows pointing downward initiating capillary flow up the strip. Any gold particles that are not complexed with antibiotics present in the milk will bind to their respective test line, forming a signal (red line) at that position. Each test strip is imprinted with two test lines and one Control line (C -line). One test line allows for the detection of tetracyclines, and the other for the detection of beta -lactam antibiotics. If the binding protein on the gold particle has engaged with either a tetracycline or a beta-lactam antibiotic present in the milk sample, the gold particle will flow past the test line corresponding to that antibiotic and reach the C-line. For visual interpretation of the test results, any test line signal intensity that is stronger than the signal at the C -line indicates a negative

result. Signal at any test line which is equal or less intense compared to th e

 